{}

Our Brands

Impact-Company-Logo-English Black-01-177x54

Welcome to the Schneider Electric Website

Welcome to our website.

How can we help you today?

cable pull switches

Question
What is the difference between a “Normal Stop” and “Emergency Stop” versions of the XY2 cable pull switches?

Issue:
What is the difference between a “Normal Stop” and “Emergency Stop” versions of the XY2 cable pull switches?

Product Line:
Cable Pull Switches

Environment:
Machine Safety Products

Cause:
Product Selection

Resolution:
The Emergency stop versions have positive opening Normally Closed contacts that latch upon tripping (positive opening) and must be manually reset.


Normal stop versions are used where a momentary, non-emergency signal is required at any point along a cable. These devices have snap acting contacts and are non-latching devices.

Schneider Electric Australia

Explore more
Range:
Users group

Discuss this topic with experts

Visit our Community for first-hand insights from experts and peers on this topic and more.
Explore more
Range: