Wiser2/SLHC Remote Connection for PICED 1.14.2 onward

In the new Firmware Wiser 2 will only be able to connect remotely using SSL/HTTPS (Port 443 or the External Port that is defined in PICED)

This means HTTP or Port 80 will now longer allow you to login remotely

Whenever you change the remote connection setting, it will force a reboot of the Wiser 2

Wiser 2 with WiFi – wiser2firmware_1_33_1.img, Wiser 2 without WiFi – SLHomeControllerFirmware_2_01_1.img