{}

Nos marques

Bienvenue sur le site Web de Schneider Electric

Bienvenue sur notre site Web.

Consulter notre FAQ

What can cause an INF4 fault on the ATV61 and ATV71 drives?

Issue:
INF4 fault on the ATV61 and ATV71.

Product Line:
ATV61 and ATV71 drives

Environment:
All

Cause:
INF4 is an Internal Zone Fabrication Error which is caused by incoherent internal data on the EEPROM.

Resolution:
* Recalibrating the drive using the diagnostic menu. (This option is only available for the field services techs)
* Change the control bloc or power board.

Schneider Electric Belgium

En savoir plus
Gamme :
Altivar 71Altivar 61
En savoir plus
Gamme :
Altivar 71Altivar 61