{}

Nossas Marcas

Impact-Company-Logo-English Black-01-177x54

Bem-vindo ao website da Schneider Electric

Bem-vindo ao nosso site.
Pesquisar perguntas frequentes
Symmetra LX Spare Parts List

Article available in these languages: Spanish




Issue

Where can I find a list of commonly replaced spare parts for the APC Symmetra LX UPS system?



Product Line

Symmetra LX



Environment

All serial numbers



Cause

The purpose of this document is to provide a user with a list of spare parts for servicing a Symmetra LX UPS.  If parts not listed are required, please contact technical support for assistance.


Resolution

Spare parts for 208/240 VAC Symmetra LX systems (Symmetra system part numbers ending in "P" or "PXR")
Power Module
  • Symmetra LX 4 kVA Power Module, 200V/208V - SYPM4KP


Battery Modules
  • APC Symmetra LX Battery Module - SYBT5
  • APC Symmetra LX Battery Module with flame retardant case (used primarily in Japan) - SYBT5FR


Intelligence Modules
  • APC Symmetra LX Intelligence Module - SYMIM5
Rack-Mounting Hardware
  • Symmetra LX Four-Post Rack-Mounting Rails - SYAOPT1
  • Symmetra LX/Symmetra RM Two-Post Rail Kit - SYOPT12
Mainframe Parts and Accessories
  • Symmetra LX frame electronics module – 200V/208V - SYAFSU13
  • Symmetra LX Input/Output wiring tray – 200V/208V - SYAFSU14
  • Symmetra LX Communications Card - SYAFSU15
  • Symmetra LX 13 U replacement door - SYAFSU2
  • Symmetra LX 19 U replacement door - SYAFSU3
  • Symmetra LX 32 U replacement door - SYAFSU5
  • Symmetra LX Castor kit - left front, right rear - SYAFSU6
  • Symmetra LX Castor kit - right front, left rear - SYAFSU7
  • Symmetra LX top panel - SYAFSU8
  • Symmetra LX 13 U left side panel - SYAFSU9L
  • Symmetra LX 19 U left side panel - SYAFSU10L
  • Symmetra LX 32 U left side panel - SYAFSU12L
  • Symmetra LX 13 U right side panel - SYAFSU9R
  • Symmetra LX 19 U right side panel - SYAFSU10R
  • Symmetra LX 32 U right side panel - SYAFSU12R


Extended Run (XR) Frame Parts and Accessories
  • APC Symmetra LX XR Communication Card - SYAFSU16 (used in Symmetra LX branded XR frames - SYAXRxxxx, SYARMXRxxxx, SYBFxxxx)
  • APC Symmetra RM XR Communication Card - SYXRCC (used in Symmetra RM branded XR frame - SYRMXR4)
  • APC Symmetra LX XR Communication Cable - 0W6002B
  • APC Symmetra LX 5U replacement door - SYAFSU1
For 220/230/240/380/400/415 VAC Symmetra LX systems (Symmetra system part numbers ending in "I" or "IXR")
Power Module
  • Symmetra LX 4 kVA Power Module, 220V/230V/240V - SYPM4KI


Battery Modules
  • APC Symmetra LX Battery Module - SYBT5


Intelligence Modules
  • APC Symmetra LX Intelligence Module - SYMIM5


Rack-Mounting Hardware
  • Symmetra LX Four-Post Rack-Mounting Rails - SYAOPT1
  • Symmetra LX/Symmetra RM Two-Post Rail Kit - SYOPT12
Mainframe Parts and Accessories
  • Symmetra LX frame electronics module – 230V - SYAFSU13I
  • Symmetra LX Input/Output wiring tray – 230V - SYAFSU14I
  • Symmetra LX Communications Card - SYAFSU15
  • Symmetra LX 13 U replacement door - SYAFSU2
  • Symmetra LX 19 U replacement door - SYAFSU3
  • Symmetra LX 32 U replacement door - SYAFSU5
  • Symmetra LX Castor kit - left front, right rear - SYAFSU6
  • Symmetra LX Castor kit - right front, left rear - SYAFSU7
  • Symmetra LX top panel - SYAFSU8
  • Symmetra LX 13 U left side panel - SYAFSU9L
  • Symmetra LX 19 U left side panel - SYAFSU10L
  • Symmetra LX 32 U left side panel - SYAFSU12L
  • Symmetra LX 13 U right side panel - SYAFSU9R
  • Symmetra LX 19 U right side panel - SYAFSU10R
  • Symmetra LX 32 U right side panel - SYAFSU12R

Extended Run (XR) Frame Parts and Accessories
  • APC Symmetra LX XR Communication Card - SYAFSU16 (used with Symmetra LX branded XR frames - SYAXRxxxx, SYARMXRxxxx, SYBFxxxx)
  • APC Symmetra RM XR Communication Card - SYXRCC (used with Symmetra RM branded XR frame - SYRMXR4)
  • APC Symmetra LX XR Communication Cable - 0W6002B
  • APC Symmetra LX 5U replacement door - SYAFSU1


Schneider Electric Brasil

Conheça mais
Linha:
Artigos que podem ser úteis
Conheça mais
Linha: