Type of Product
|
*22 mm Push Button (metal)
|
**22 mm Push Button (plastic)
| ***22mm Push Button (plastic) |
****30 mm Push Button (metal)
|
****30 mm Push Button (plastic)
|
****30 mm Push Button (metal, square)
|
Mounting Hole Diameter
|
22.5 mm
|
22.5 mm
| 22.5 mm |
31 mm (1.22 in)
|
31 mm (1.22 in)
|
31 mm (1.22 in)
|
Approvals
|
UL Listed File E164353,
CCN NKCR
UL Recognized File E164353. CCN NKCR2
|
UL Listed File E164353, CCN NKCR
UL Recognized File E164353., CCN NKCR2
| UL File E164353, CCN NKCR |
UL File E78403. CCN NKCR
|
UL File E78403. CCN NKCR
|
UL File E78403. CCN NKCR
|
CSA File LR44087.
Class 3211-03
|
CSA File LR44087.
Class 3211-03
| CSA File LR44087-122 Class 3211-03 |
CSA File LR25490.
Class 3211-03
|
CSA File LR25490.
Class 3211-03
|
CSA File LR25490.
Class 3211-03
|
Conforming to Standards
|
CE Marked RoHS Compliant
|
CE Marked RoHS Compliant
|
CE Marked RoHS Compliant
|
CE Marked RoHS Compliant
|
CE Marked RoHS Compliant
|
CE Marked RoHS Compliant
|
EN/IEC 60947-1,
EN/IEC 60947-5-1,
EN/IEC 60947-5-4,
EN/IEC 60947-5-5
|
EN/IEC 60947-1,
EN/IEC 60947-5-1,
EN/IEC 60947-5-4,
EN/IEC 60947-5-5
| EN/IEC 60947-1, EN/IEC 60947-5-1 for push buttons, pilot lights, illuminated push buttons and selector switches EN/IEC 60947-1, EN/IEC 60947-5-1, EN/IEC 60947-5-5, |
EN/IEC 60947-1
|
EN/IEC 60947-1
|
EN/IEC 60947-1
|
EN/IEC 60204-1 and
EN/ISO 13850: 2006 (trigger action and mechanical latching emergency stop push buttons)
|
EN/IEC 60204-1 and
EN/ISO 13850: 2006 (trigger action and mechanical latching emergency stop push button).
| EN/IEC 60204-1 and EN/ISO 13850 for Emergency Stop trigger action push buttons |
EN/IEC60947-5-1
|
EN/IEC60947-5-1
|
EN/IEC60947-5-1
|
EN/IEC 60364-5-53 (emergency switching of mechanical latching push buttons)
|
EN/IEC 60364-5-53 (emergency switching of mechanical latching push buttons)
| |
EN/IEC60947-5-4
|
EN/IEC60947-5-4
|
EN/IEC60947-5-4
|
—
|
EN81-1 (emergency stop trigger action and mechanical latching push buttons with mechanical state indicator)
| | | | |
JIS C 4520
|
JIS C 4520
| |
JIS C 4520 and 852
|
JIS C 4520 and 852
|
JIS C 4520 and 852
|
UL 508
|
UL 508
| UL 508 |
UL 508
|
UL 508
|
UL 508
|
CSA C22.2 No.14
|
CSA C22.-2 No.14
| CSA C22 No.14 |
CSA C22.2 No.14
|
CSA C22.2 No.14
|
CSA C22.2 No.14
|
GOST
|
GOST
| | | | |
CCC
|
CCC
| CCC | | | |
| | GB 14048.5 for all XB7 range | | | |
Degree of Protection
|
IP65, IP69, IP69K
|
IP65, IP69, IP69K
| IP54, IP65 |
IP65
|
IP65
|
IP66
|
IP66 for booted
|
IP66 for booted
|
—
|
—
|
—
|
—
|
NEMA 1, 2, 3, 4, 4X, 12, 13
|
NEMA 1, 2, 3, 3R, 4, 4X, 12, 13
| NEMA 3, 4, 12 |
NEMA 1, 2, 3, 3R, 4, 12, 13
| NEMA 1, 2, 3, 3R, 4, 4X, 12, 13 | NEMA 1, 2, 3, 3R, 4, 12, 13 |
Operating Temperature F° (C°)
|
-40 to 158 (-40 to 70)
|
-40 to 158 (-40 to 70)
|
-13 to 158 (-25 to 70)
|
-22 to 140 (-30 to 60)
|
-22 to 140 (-30 to 60)
|
-22 to 140 (-30 to 60)
|
Storage Temperature F° (C°)
|
-40 to 158 (-40 to 70)
|
-40 to 158 (-40 to 70)
|
-40 to 158 (-40 to 70)
|
-40 to 158 (-40 to 70)
|
-40 to 158 (-40 to 70)
|
-40 to 158 (-40 to 70)
|
Electric Shock Protection
|
Class I
|
Class I
|
—
|
Class II
|
Class II
|
Class II
|
Electrical Consumption
| | | | | | |
LED
|
24 Vac/Vdc: 18 mA
|
24 Vac/Vdc: 18 mA
|
Illuminated Push Buttons: 24V - 18mA 120V - 12mA 230V - 22mA
Pilot Lights 24V - 20mA 120V - 18mA 230V - 16mA
|
Incandescent and LED bulbs. For ratings, see Standard Light Modules.
|
Incandescent and LED bulbs. For ratings, see Standard Light Modules.
|
Incandescent
|
120 Vac: 14 mA
|
120 Vac: 14 mA
|
240 Vac: 14 mA
|
240 Vac: 14 mA
|
Rated Operational
Characteristics
|
AC-15; B600
Ue = 600 Vac and le = 1.2 A
Ue = 240 Vac and
le = 3A
Ue = 120 Vac and le = 6A
Continuous 10 A
|
AC-15; B600
Ue = 600 Vac and le = 1.2 A
Ue = 240 Vac and le = 3 A
Ue = 120 Vac and le = 6 A
Continuous 10 A
| AC-14; D300 Ue = 240 Vac and le = 0.3A Ue = 120 Vac and le = 0.6A Continuous 4 A |
AC-15; A600
Continuous 10 A
|
AC-15; A600
Continuous 10 A
|
AC-15; A600
Continuous 10 A
|
DC-13; Q600
Ue = 600 Vdc and le = 0.1 A
Ue = 250 Vdc and le = 0.27 A
Ue = 125 Vdc and le = 0.55 A
|
DC-13; Q600
Ue = 600 Vdc and le = 0.1 A
Ue = 250Vdc and le = 0.27 A
Ue = 125 Vdc and le = 0.55 A
| DC-13; R300 Ue = 250 Vdc and le = 0.1A Ue = 125 Vdc and le = 0.22A |
DC-13; Q600
Ue = 600 Vdc and le = 0.1 A
Ue = 250 Vdc and le = 0.27 A
Ue = 125 Vdc and le = 0.55 A
|
DC-13; Q600
Ue = 600 Vdc and le = 0.1 A
Ue = 250 Vdc and le = 0.27 A
Ue = 125 Vdc and le = 0.55 A
|
DC-13; Q600
Ue = 600 Vdc and le = 0.1 A
Ue = 250 Vdc and le = 0.27 A
Ue = 125 Vdc and le = 0.55 A
|
Connection Type
|
IP20 Fingersafe Screw or Spring Terminal
| Screw and captive clamp terminal connections Faston clip connections (pilot lights) |
IP20 Fingersafe Screw Terminal
|
Screw Terminal:
|
Spring Terminal:
|
Cable Size
|
1 x 24 AWG (0.22 mm²) min.
2 x 14 AWG (2.5 mm²) max.
2 x 16 AWG (1.5 mm²) max.
|
1 x 24 AWG (0.22 mm²) min.
2 x 14 AWG (2.5 mm²) max.
2 x 16 AWG (1.5 mm²) max.
|
1 x 24 AWG (0.22 mm²) min.
2 x 16 AWG (1.5 mm²) max
|
1 x 24 AWG (0.22 mm²) min.
2 x 16 AWG (1.5 mm²) max
|
1 x 24 AWG (0.2 2mm²) min.
2 x 16 AWG (1.5 mm²) max
|
Digest Location
|
XB4
|
XB5
|
XB7
|
Type K
|
Type SK
|
KX
|