PowerLogic PM5000 Series (PM5100, PM5300, PM5500) Modbus Register List

Issue Register list for Modbus communication Product Line PM5110, PM5330, PM5340, PM5560, and PM5563 Environment Power Meter Communications Modbus Register List Cause PM5000 series register list is...

Wiring of RS485 Communications Networks

Issue This document attempts to explain correct methods of wiring RS485 communication networks in industrial environments based on various application notes and technical articles. Environment RS485...

What programming software is used to program the M241?

Issue: What programming software is used to program the M241? Product Line: TM241, M241 Resolution: The programming software for the M241 is called Machine Expert. Below is the link for it....

What is a routine test certificate and type test report ?

The document attached explains the difference between a routine test certificate and a type test report.

What can cause an output phase fault (OPF) on an ATV312 or ATV31?

Issue: OPF on Altivar 31/312 Drives Product Line: ATV312 ATV31 Environment: All models and serial numbers Cause: This fault occurs when the drive has been commanded to run the motor but no or very...

What is the PM8000's COMTRADE File Format and can it be changed?

Issue What is the COMTRADE file name/time format, and can it be changed? Product Line PowerLogic PM8000 Series Environment COMTRADE File Resolution The COMTRADE files (.cfg and .dat) from a sag/swell...

Is there a download link for SoMachine Basic 1.6?

Issue: Where to find and download SoMachine Basic. Product Line: SoMachine Basic Environment: SoMachine Basic Resolution: As of 10/9/2018 the SoMachine Basic software is version 1.6 sp2 is no longer...

Procedure to send commands over Modbus to PM5000 using Modbus Tester

Issue: Customer wants to send a command to a PM5000 to perform remote configuration or a meter reset. Product Line: PM5100 (PM5110) PM5300 (PM5330, PM5340) PM5500 (PM5560, PM5563) Environment: Remote...

Show more
Popular Video FAQsPopular Videos
Show more
Learn more through our Generic Knowledge FAQsGeneral Knowledge
3 Easy Ways to Choose the Right Contactor

There are three way to selection of contactor: 1. Types of applications, there are many application characteristics (utilization categories): such as AC-1, AC-3, AC-4 and other categories....

Apa alternatif replacement battery UPS SURT15KRMXLI jika APCRBC140 tidak...

Apa alternatif replacement battery UPS SURT15KRMXLI jika APCRBC140 tidak ready stock? ======================================================================= Untuk alternatifnya bisa menggunakan...

What is Power Factor Correction (PFC) - Does it help conserve energy?

Issue: What is Power Factor Correction (PFC) - Does it help conserve energy? Answer: Power Factor Correction (PFC) doesn't directly reduce the overall electric consumption of a device or system,...

What is the Contactor?

Contactor is electrically operated switches using by electro mechanical systems. There are 2 functions of contact: main contact and auxilliary contacts. There are also have two typical contacts on...

Voltage, Current and Resistance Explained

Issue: How do I remember the relationship of voltage, current and resistance in an electrical system? Environment: N/A Solution: Voltage (unit of measurement - volt) is like the water pressure in the...

What is the selection criterion of Circuit Breakers for the Capacitor bank...

The selection should be done after derating the Circuit Breaker taking into consideration voltage variation and capacitors tolerances that could increase nominal current up to 1.5In. The Derating...