Search FAQs
How to select replacement for XPSAF and XPSAFL
Commercial Reference | Replacement Commercial Reference |
---|---|
XPSAF5130 | XPSUAF13AP |
XPSAF5130P | XPSUAF13AP |
Replacement/substitution according to the terminal connector:
Wiring Emergency Stop diagram ZPSAF & XPSUAF
Wiring Emergency Stop single channel diagram ZPSAF & XPSUAF
Wiring Emergency Stop in series diagram ZPSAF & XPSUAF
Wiring Safety Switch diagram ZPSAF & XPSUAF
XPSAFL is replaced by XPSUAF
Commercial Reference | Replacement Commercial Reference |
---|---|
XPSAFL5130 | XPSUAF13AP |
XPSUAF13AP | XPSUAF13AP |
Replacement/substitution according to the terminal connector:
Wiring Emergency Stop diagram ZPSAFL & XPSUAF
Wiring Emergency Stop single channel diagram ZPSAFL & XPSUAF
Wiring Emergency Stop in series diagram ZPSAFL & XPSUAF
Wiring Safety Switch diagram ZPSAFL & XPSUAF
Wiring Safety Light Curtains or RFID Sensors* diagram ZPSAF & XPSUAF
⚠ CAUTION ⚠
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. If you have any suggestions for improvements or amendments or have found errors in this publication, please notify us.
You agree not to reproduce, other than for your own personal, noncommercial use, all or part of this document on any medium whatsoever without permission of Schneider Electric, given in writing. You also agree not to establish any hypertext links to this document or its content. Schneider Electric does not grant any right or license for the personal and noncommercial use of the document or its content, except for a non-exclusive license to consult it on an "as is" basis, at your own risk. All other rights are reserved.
All pertinent state, regional, and local safety regulations must be observed when installing and using this product. For reasons of safety and to help ensure compliance with documented system data, only the manufacturer should perform repairs to components.
When devices are used for applications with technical safety requirements, the relevant instructions must be followed.
Failure to use Schneider Electric software or approved software with our hardware products may result in injury, harm, or improper operating results.
Failure to observe this information can result in injury or equipment damage.
© 2021 Schneider Electric. All rights reserved.