Use the Secure disposal checklist when disposing a ConneXium Industrial Firewall (TCSEFEA23F3F22) to help prevent potential disclosure of data.
Secure disposal checklist
For more information on the ConneXium Industrial Firewall, see https://www.se.com/us/en/download/document/NHA1572901/.
Secure disposal checklist
Task | Description | Completed |
Record activities | Document disposal actions according to your company’s policies and standards to keep a record of activities. | □ |
Factory Reset the device | To reset the Tofino SA back to its default state as shipped from the factory with configuration and logs erased, you can perform a 'Factory Reset' Confirm that power is applied to the Tofino SA and it has completed its start-up initialization. | □ |
Press, then release the "Save Load Reset" button three times so that the three LEDs are illuminated. On the first press, the " 1/s" indicator will be illuminated; on the second press, the " 2/L" indicator will be illuminated; and on the third press, the "V.24/R" indicator will be illuminated. | □ | |
After a few seconds, the Tofino SA will start its factory reset sequence. The " 1/s", " 2/L", "V.24/R", "Mode" and "Fault" indicators will flash simultaneously while the factory reset is being performed. | □ | |
Once the factory reset is complete, the " 1/s", " 2/L", "V.24/R", "Mode" and "Fault" indicators will turn off. This LED pattern confirms that the Tofino SA is passive and passing traffic without filtering. If the Mode LED is ON, repeat steps 1 through 3 above. If the LEDs are different from the above, please contact technical support. | □ | |
Decommission and sanitize | Follow decommission and sanitization tasks as described by your organization or contact your Network Administrator. | □ |
Perform records tracking sanitization tasks to remove records in related systems. For example: monitoring SNMP servers. | □ | |
Disposal and reuse | After usage, this product must be disposed of properly as electronic waste, in accordance with the current disposal regulations of your county, state and country. | □ |
For more information on the ConneXium Industrial Firewall, see https://www.se.com/us/en/download/document/NHA1572901/.