{}

Our Brands

Impact-Company-Logo-English Black-01-177x54

Welcome to the Schneider Electric Website

Welcome to our website.
How can we help you today?
Modbus Broadcast report

Goals and Symptoms

Successful broadcast request on modbus on Premium/Micro PLC (SCP111/114 or SCY) returns 16#00FF as result in second word of management table (instead of 16#0000 for a correct exchange in other protocols)
Successful broadcast request on modbus on M340 PLC returns 16#0001 as result in second word of management table (instead of 16#0000 for a correct exchange in other protocols)

Causes and Fixes

To take into account when performing broadcast over Premium/Micro and M340.

Schneider Electric India

Explore more
Range:
Articles that might be helpful Users group

Discuss this topic with experts

Visit our Community for first-hand insights from experts and peers on this topic and more.
Explore more
Range: