{}

브랜드

Impact-Company-Logo-English Black-01-177x54

슈나이더 일렉트릭 코리아 웹사이트에 방문해 주셔서 감사합니다.

슈나이더 일렉트릭 코리아 웹사이트 방문자 분들 모두 환영합니다.

FAQ 검색

Configuration Manager Tool 2020 - "No matching constructor found on type" error when launching the tool

Issue
When first launching CM Tool 2020 on a server (usually older versions of OS) it will ask for .NET 4.6 to be installed as it is not present. After installing the .NET and rebooting the server the CM Tool will still fail to open and will throw the following error:
"No matching constructor found on type
'ConfigurationManager.ViewModels.ConfigurationManagerVM'. You can use the Arguments or FactoryMethod directives to construct this type.
"



Product Line
Configuration Manager Tool 2020

Environment
Upgrades
Migrations

Cause
This issue happens due to a missing .NET framework component.

Resolution
1) Apply all the outstanding Windows Updates on the server
2) Install .NET 4.7.2 framework

슈나이더 일렉트릭 Korea

자세히 알아보기
제품군
자세히 알아보기
제품군