In Vijeo Designer, where can I find the images used in the "resources" if I'm not the original creator of the project

Product :

Vijeo Designer

Issue:

If you are not the person who created the resource, and selected the image you want for the different states, and you wish to retrieve those pictures for other purposes, where are those images stored?

Resolution:

You need to go in your Vijeo Manager. By default the location will be:

C:\Users\Public\Documents\Vijeo-Designer 6.2\

Vijeo Manager default location

In that Vijeo Manager folder, find your project name and navigate to

C:\Users\Public\Documents\Vijeo-Designer 6.2\Vijeo-Manager\"project name"\Build\Projects\"target name"

*Make sure your project has been built.

Resources images

You should find a bunch of bmp files. These are your pictures processed by Vijeo Manager.