Issue:
User name and password lengths for InfraStruXure Central and Netbotz appliances for an SNMP version 3 inform.
Product Line:
NetBotz
InfraStruxure Central
Environment:
Netbotz SNMP v3
Cause:
SNMP version 3 requirements
Resolution:
v3 informs only work under certain circumstances.
md5/des user/password must be 8-15 characters
md5/aes user/password must be 8-15 characters
sh1/aes user/password must be 16+ characters
sh1/des user/password must be 16+ characters
for md5 the user name and password only work if they are between 8-15 characters.
for sh1 the user name and password only work if they are >16 characters.
User name and password lengths for InfraStruXure Central and Netbotz appliances for an SNMP version 3 inform.
Product Line:
NetBotz
InfraStruxure Central
Environment:
Netbotz SNMP v3
Cause:
SNMP version 3 requirements
Resolution:
v3 informs only work under certain circumstances.
md5/des user/password must be 8-15 characters
md5/aes user/password must be 8-15 characters
sh1/aes user/password must be 16+ characters
sh1/des user/password must be 16+ characters
for md5 the user name and password only work if they are between 8-15 characters.
for sh1 the user name and password only work if they are >16 characters.
Released for: Schneider Electric Philippines
Issue:
User name and password lengths for InfraStruXure Central and Netbotz appliances for an SNMP version 3 inform.
Product Line:
NetBotz
InfraStruxure Central
Environment:
Netbotz SNMP v3
Cause:
SNMP version 3 requirements
Resolution:
v3 informs only work under certain circumstances.
md5/des user/password must be 8-15 characters
md5/aes user/password must be 8-15 characters
sh1/aes user/password must be 16+ characters
sh1/des user/password must be 16+ characters
for md5 the user name and password only work if they are between 8-15 characters.
for sh1 the user name and password only work if they are >16 characters.
User name and password lengths for InfraStruXure Central and Netbotz appliances for an SNMP version 3 inform.
Product Line:
NetBotz
InfraStruxure Central
Environment:
Netbotz SNMP v3
Cause:
SNMP version 3 requirements
Resolution:
v3 informs only work under certain circumstances.
md5/des user/password must be 8-15 characters
md5/aes user/password must be 8-15 characters
sh1/aes user/password must be 16+ characters
sh1/des user/password must be 16+ characters
for md5 the user name and password only work if they are between 8-15 characters.
for sh1 the user name and password only work if they are >16 characters.
Released for: Schneider Electric Philippines
















Need help?
Start here!
Find answers now. Search for a solution on your own, or connect with one of our experts.
Contact Support
Reach out to our customer care team to receive more information, technical support, assistance with complaints and more.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Search FAQs
Search topic-related frequently asked questions to find answers you need.
Contact Sales
Start your sales inquiry online and an expert will connect with you.