{}

Our Brands

Impact-Company-Logo-English Black-01-177x54

Welcome to the Schneider Electric Website

Welcome to our website.
Search FAQs
How to reduce the launching waiting time of control Expert 15.x with floating license ?

Issue:

How to reduce the launching waiting time of control Expert 15.x with floating license ?

Product Line:

EcoStruxure Control Expert

Environment:

EcoStruxure Control Expert

Resolution:

-Edit the Group Policy : WIN +R  then enter : gpedit.msc

- Go on Computer Configuration / Windows Settings /

Security Settings / Public Key Policies /Certificate Pass Validation Settings

- from this page select tab Network retrieval, check option Define these policy settings and apply these values:

1 instead of 15 (Default URL) and 2 instead to 20 (Default path validation).
SLOW.JPG

Schneider Electric Saudi Arabia

Explore more
Range:
Articles that might be helpful Users group

Discuss this topic with experts

Visit our Community for first-hand insights from experts and peers on this topic and more.
Explore more
Range: