How to determine an appropriate IP address based on the subnet mask.

Issue
Some devices require the use of a subnet mask. If not set properly the symptoms will be no communications between the device and software. All settings will look normal and all static address requirements will be filled.

Product Line
All Ethernet Devices

Environment
Network Communications


Cause
In a situation where a customer is attempting to directly connect to the meter for a pre-deployment configuration where it is necessary to assign a temporary static IP address to the customer's computer based off the subnet mask assigned to the meter. In most situations, customers will use a standard subnet mask of 255.255.255.0. This is a standard class C network also known as a /24 that allows the full use of all IP addressing in the host address's range.

A host IP address of 10.10.10.1 with a subnet mask of 255.255.255.0 would allow the host to communicate with any other IP address of 10.10.10.1-254. (1 is already used and 0, 255 is reserved)

This is simple and easy to calculate an IP address that the meter can use and still communicate with a server or the customer's computer.

Resolution
Step 1: Locate the netmask assigned to the meter you are wanting to communicate with. Note the / class number it is a member of.
/ ClassAddressesHostsNetmask Class C amount
3042255.255.255.2521/64
2986255.255.255.2481/32
281614255.255.255.2401/16
273230255.255.255.2241/8
266462255.255.255.1921/4
25128126255.255.255.1281/2
24256254255.255.255.01
23512510255.255.254.02
2210241022255.255.252.04
2120482046255.255.248.08
2040964094255.255.240.016
1981928190255.255.224.032
181638416382255.255.192.064
173276832766255.255.128.0128
166553665534255.255.0.0256


Step 2: Locate the corresponding class block. Then decide which Address range your meter address falls into. Addresses in the address range are valid for that class network.

Example: If you have a /25 with an IP address of  10.10.10.200 your meter falls into the first chart  /25 and the second row labeled 129-254.  Therefore you should set the computer IP address to 10.10.10.129-254 (Excluding 200).

/25
Network NumberAddress RangeBroadcast Address
01-126127
128129-254255

/26
Network #Address RangeBroadcast Address
01-6263
6465-126127
128129-190191
192193-254255

/27
Network NumberAddress RangeBroadcast Address
01-3031
3233-6263
6465-9495
9697-126127
128129-158159
160161-190191
192193-222223
224225-254255

/28
Network NumberAddress RangeBroadcast Address
01-1415
1617-3031
3233-4647
4849-6263
6465-7879
8081-9495
9697-110111
112113-126127
128129-142143
144145-158159
160161-174175
176177-190191
192193-206207
208209-222223
224225-238239
240241-254255

/29
Network numberAddress RangeBroadcast Address
01-67
89-1415
1617-2223
2425-3031
3233-3839
4041-4647
4849-5455
5657-6263
6465-7071
7273-7879
8081-8687
8889-9495
9697-102103
104105-110111
112113-118119
120121-126127
128129-134135
136137-142143
144145-150151
152153-158159
160161-166167
168169-174175
176177-182183
184185-190191
192193-198199
200201-206207
208209-214215
216217-222223
224225-230231
232233-238239
240241-246247
248249-254255

/30
Network NumberAddress RangeBroadcast Address
01-23
45-67
89-1011
1213-1415


/30
01-23
45-67
89-1011
1213-1415
1617-1819
2021-2223
2425-2627
2829-3031
3233-3435
3637-3839
4041-4243
4445-4647
4849-5051
5253-5455
5657-5859
6061-6263
6465-6667
6869-7071
7273-7475
7677-7879
8081-8283
8485-8687
8889-9091
9293-9495
9697-9899
100101-102103
104105-106107
108109-110111
112113-114115
116117-118119
120121-122123
124125-126127
128129-130131
132133-134135
136137-138139
140141-142143
144145-146147
148149-150151
152153-154155
156157-158159
160161-162163
164165-166167
168169-170171
172173-174175
176177-178179
180181-182183
184185-186187
188189-190191
192193-194195
196197-198199
200201-202203
204205-206207
208209-210211
212213-214215
216217-218219
220221-222223
224225-226227
228229-230231
232233-234235
236237-238239
240241-242243
244245-246247
248249-250251
252253-254255


Schneider Electric Thailand

Related products for Schneider Electric Thailand
Range:
Articles that might be helpful Users group

Discuss this topic with experts

Visit our Community for first-hand insights from experts and peers on this topic and more.
Related products for Schneider Electric Thailand
Range: