Search FAQs
Symmetra LX Spare Parts List
Issue
Where can I find a list of commonly replaced spare parts for the APC Symmetra LX UPS system?
Product Line
Symmetra LX
Environment
All serial numbers
Cause
The purpose of this document is to provide a user with a list of spare parts for servicing a Symmetra LX UPS. If parts not listed are required, please contact technical support for assistance.
Resolution
Spare parts for 208/240 VAC Symmetra LX systems (Symmetra system part numbers ending in "P" or "PXR")
Power Module
- Symmetra LX 4 kVA Power Module, 200V/208V - SYPM4KP
Battery Modules
- APC Symmetra LX Battery Module - SYBT5
- APC Symmetra LX Battery Module with flame retardant case (used primarily in Japan) - SYBT5FR
Intelligence Modules
- APC Symmetra LX Intelligence Module - SYMIM5
Rack-Mounting Hardware
- Symmetra LX Four-Post Rack-Mounting Rails - SYAOPT1
- Symmetra LX/Symmetra RM Two-Post Rail Kit - SYOPT12
Mainframe Parts and Accessories
- Symmetra LX frame electronics module – 200V/208V - SYAFSU13
- Symmetra LX Input/Output wiring tray – 200V/208V - SYAFSU14
- Symmetra LX Communications Card - SYAFSU15
- Symmetra LX 13 U replacement door - SYAFSU2
- Symmetra LX 19 U replacement door - SYAFSU3
- Symmetra LX 32 U replacement door - SYAFSU5
- Symmetra LX Castor kit - left front, right rear - SYAFSU6
- Symmetra LX Castor kit - right front, left rear - SYAFSU7
- Symmetra LX top panel - SYAFSU8
- Symmetra LX 13 U left side panel - SYAFSU9L
- Symmetra LX 19 U left side panel - SYAFSU10L
- Symmetra LX 32 U left side panel - SYAFSU12L
- Symmetra LX 13 U right side panel - SYAFSU9R
- Symmetra LX 19 U right side panel - SYAFSU10R
- Symmetra LX 32 U right side panel - SYAFSU12R
Extended Run (XR) Frame Parts and Accessories
- APC Symmetra LX XR Communication Card - SYAFSU16 (used in Symmetra LX branded XR frames - SYAXRxxxx, SYARMXRxxxx, SYBFxxxx)
- APC Symmetra RM XR Communication Card - SYXRCC (used in Symmetra RM branded XR frame - SYRMXR4)
- APC Symmetra LX XR Communication Cable - 0W6002B
- APC Symmetra LX 5U replacement door - SYAFSU1
For 220/230/240/380/400/415 VAC Symmetra LX systems (Symmetra system part numbers ending in "I" or "IXR")
Power Module
- Symmetra LX 4 kVA Power Module, 220V/230V/240V - SYPM4KI
Battery Modules
- APC Symmetra LX Battery Module - SYBT5
Intelligence Modules
- APC Symmetra LX Intelligence Module - SYMIM5
Rack-Mounting Hardware
- Symmetra LX Four-Post Rack-Mounting Rails - SYAOPT1
- Symmetra LX/Symmetra RM Two-Post Rail Kit - SYOPT12
Mainframe Parts and Accessories
- Symmetra LX frame electronics module – 230V - SYAFSU13I
- Symmetra LX Input/Output wiring tray – 230V - SYAFSU14I
- Symmetra LX Communications Card - SYAFSU15
- Symmetra LX 13 U replacement door - SYAFSU2
- Symmetra LX 19 U replacement door - SYAFSU3
- Symmetra LX 32 U replacement door - SYAFSU5
- Symmetra LX Castor kit - left front, right rear - SYAFSU6
- Symmetra LX Castor kit - right front, left rear - SYAFSU7
- Symmetra LX top panel - SYAFSU8
- Symmetra LX 13 U left side panel - SYAFSU9L
- Symmetra LX 19 U left side panel - SYAFSU10L
- Symmetra LX 32 U left side panel - SYAFSU12L
- Symmetra LX 13 U right side panel - SYAFSU9R
- Symmetra LX 19 U right side panel - SYAFSU10R
- Symmetra LX 32 U right side panel - SYAFSU12R
Extended Run (XR) Frame Parts and Accessories
- APC Symmetra LX XR Communication Card - SYAFSU16 (used with Symmetra LX branded XR frames - SYAXRxxxx, SYARMXRxxxx, SYBFxxxx)
- APC Symmetra RM XR Communication Card - SYXRCC (used with Symmetra RM branded XR frame - SYRMXR4)
- APC Symmetra LX XR Communication Cable - 0W6002B
- APC Symmetra LX 5U replacement door - SYAFSU1
Released for:Schneider Electric UK
Explore more
Range:
Explore more
Range: