{}

Our Brands

Impact-Company-Logo-English Black-01-177x54

Welcome to the Schneider Electric Website

Welcome to our website.
How can we help you today?
How to save and load current values in a .csv file using SoMachine/Machine Expert - Basic?

You can save/load the current values in a .cvs file using the following method:

Save Data:

  • Go to Commissioning tab
  • Select Controller Memory Management
  • In the Destination field, select the folder where you want to save the current values
  • Then select which range of %M or %MW you want to save
  • And finally press the button "Backup from Controller"


-


Restore data:

  • Select the option Restore to Controller
  • Select the .csv file in your PC
  • Press the button "Restore to Controller"

Schneider Electric UK

Explore more
Range:
Articles that might be helpful Users group

Discuss this topic with experts

Visit our Community for first-hand insights from experts and peers on this topic and more.
Explore more
Range: