{}

Our Brands

Impact-Company-Logo-English Black-01-177x54

Welcome to the Schneider Electric Website

Welcome to our website.
How can we help you today?
How to select replacement for XPSBCE, XPSBF, XPSVC and XPSDMB

Article available in these languages: Czech, Dutch

XPSBCE is replaced by XPSUS 24V
image.png

Commercial ReferenceReplacement Commercial Reference
XPSBCE3110CXPSUS12AC
XPSBCE3110PXPSUS12AP

Replacement/substitution according to the terminal connector:
image.png

Wiring Two-Hand Control* (24VAC/DC) diagram XPSBCE & XPSUS
image.png

XPSBCE is replaced by XPSUS - 115V/230V
image.png
Commercial ReferenceReplacement Commercial Reference
XPSBCE3410CXPSUS32AC
XPSBCE3410PXPSUS32AP
XPSBCE3710CXPSUS32AC
XPSBCE3710PXPSUS32AP

Replacement/substitution according to the terminal connector:
image.png

Wiring Two-Hand Control* (115/230VAC) diagram XPSBCE & XPSUS
image.png

XPSBF is replaced by XPSUS
image.png
Commercial ReferenceReplacement Commercial Reference
XPSBF1132XPSUS12AP
XPSBF1132PXPSUS12AP

Replacement/substitution according to the terminal connector:
image.png
Wiring Two-Hand Control* (24VAC/DC) diagram XPSBF & XPSUS

image.png
XPSVC is replaced by XPSUS
image.png
Commercial ReferenceReplacement Commercial Reference
XPSVC1132XPSUS12AP
XPSVC1132PXPSUS12AP

Replacement/substitution according to the terminal connector:
image.png
Wiring Enabling Switch diagram XPSVC & XPSUAF
image.png
XPSDMB is replaced by XPSUS
image.png
Commercial ReferenceReplacement Commercial Reference
XPSDMB1132XPSUS12AP
XPSDMB1132PXPSUS12AP

Replacement/substitution according to the terminal connector:
image.png
Wiring Coded Magnetic Switches diagram XPSDMB & XPSUS
image.png

image.png
image.png

CAUTION

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. If you have any suggestions for improvements or amendments or have found errors in this publication, please notify us.

You agree not to reproduce, other than for your own personal, noncommercial use, all or part of this document on any medium whatsoever without permission of Schneider Electric, given in writing. You also agree not to establish any hypertext links to this document or its content. Schneider Electric does not grant any right or license for the personal and noncommercial use of the document or its content, except for a non-exclusive license to consult it on an "as is" basis, at your own risk. All other rights are reserved.

All pertinent state, regional, and local safety regulations must be observed when installing and using this product. For reasons of safety and to help ensure compliance with documented system data, only the manufacturer should perform repairs to components.

When devices are used for applications with technical safety requirements, the relevant instructions must be followed.

Failure to use Schneider Electric software or approved software with our hardware products may result in injury, harm, or improper operating results.

Failure to observe this information can result in injury or equipment damage.

© 2021 Schneider Electric. All rights reserved.

Schneider Electric UK

Explore more
Product:
Users group

Discuss this topic with experts

Visit our Community for first-hand insights from experts and peers on this topic and more.
Explore more
Product: