How do you fit Acti9 Arc Fault Device (Acti9 Active/iARC) on Isobar P?
Recommended Solution 1:
Acti9 Active AFDDs (iCV40H) can be fitted on Isobar P – Hybrid or Standalone Active distribution boards.
This is the list of AFDDs references that can be used are mentioned below :
  • A9TDFD606
  • A9TDFD610
  • A9TDFD616
  • A9TDFD620
  • A9TDFD625
  • A9TDFD632
They are accessible through the range Acti9 Active : https://www.se.com/uk/en/product-range/45435131-acti9-active/47506957254-products/
Once you have selected the right product, here are the instructions to mount it on Isobar P  - Hybrid  or Standalone Active distribution boards.
Refer to the instruction sheet: See Attached file.

Recommended Solution 2:
Acti9 iARC AFDDs cannot be fitted directly on the pan assembly of Isobar P distribution boards.
It’s recommended to fit on Acti9 Extension Enclosure. For more details refer below:
https://www.se.com/uk/en/faqs/FAQ000222877/

Schneider Electric UK

Attachment(s)
GDE66871-00 (1).pdf [5.63 MB]
How do you fit Acti9 Arc Fault Device (Acti9 Active/iARC) on Isobar P?
Recommended Solution 1:
Acti9 Active AFDDs (iCV40H) can be fitted on Isobar P – Hybrid or Standalone Active distribution boards.
This is the list of AFDDs references that can be used are mentioned below :
  • A9TDFD606
  • A9TDFD610
  • A9TDFD616
  • A9TDFD620
  • A9TDFD625
  • A9TDFD632
They are accessible through the range Acti9 Active : https://www.se.com/uk/en/product-range/45435131-acti9-active/47506957254-products/
Once you have selected the right product, here are the instructions to mount it on Isobar P  - Hybrid  or Standalone Active distribution boards.
Refer to the instruction sheet: See Attached file.

Recommended Solution 2:
Acti9 iARC AFDDs cannot be fitted directly on the pan assembly of Isobar P distribution boards.
It’s recommended to fit on Acti9 Extension Enclosure. For more details refer below: 
https://www.se.com/uk/en/faqs/FAQ000222877/

 

Schneider Electric UK

Attachment(s)
GDE66871-00 (1).pdf [5.63 MB]
Explore more
Range:
Explore more
Range:
Users group

Discuss this topic with experts

Visit our Community for first-hand insights from experts and peers on this topic and more.
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Range:
Explore more
Range:
move-arrow-top
Your browser is out of date and has known security issues.

It also may not display all features of this website or other websites.

Please upgrade your browser to access all of the features of this website.

Latest version for Google Chrome, Mozilla Firefox or Microsoft Edgeis recommended for optimal functionality.
Your browser is out of date and has known security issues.

It also may not display all features of this website or other websites.

Please upgrade your browser to access all of the features of this website.

Latest version for Google Chrome, Mozilla Firefox or Microsoft Edgeis recommended for optimal functionality.