{}

Our Brands

Impact-Company-Logo-English Black-01-177x54
Your browser is out of date and has known security issues.

It also may not display all features of this website or other websites.

Please upgrade your browser to access all of the features of this website.

Latest version for Google Chrome, Mozilla Firefox or Microsoft Edgeis recommended for optimal functionality.
How can we help you today?
video: How to set POWERLINK between Altivar and B&R PLCs ?
This video explains How to set POWERLINK communication between Altivar Drives and B&R PLCs using the POWERLINK module VW3A3619 with SoMove and Automation Studio.



Download the POWERLINK XDD files VW3A3619 here: https://www.se.com/in/en/download/document/POWERLINK_XDD_VW3A3619/

Download the POWERLINK adresses:
- ATV320 Communication parameters files here: https://www.se.com/ww/en/download/document/NVE41316/
- ATV340 Communication parameters files here: https://www.se.com/ww/en/download/document/NVE61728/
- ATV600 Communication parameters files here: https://www.se.com/ww/en/download/document/EAV64332/
- ATV900 Communication parameters files here: https://www.se.com/ww/en/download/document/NHA80944/

Download the latest version of the DTM:
- Altivar ATV320 DTM here: https://www.se.com/ww/en/download/document/ATV320_DTM_Library/
- Altivar ATV340 DTM here: https://www.se.com/ww/en/download/document/ATV340_DTM_LibraryEN/
- Altivar ATV600 DTM here: https://www.se.com/ww/en/download/document/ATV6xx_DTM_Library_EN/
- Altivar ATV900 DTM here: https://www.se.com/ww/en/download/document/ATV9xx_DTM_Library_EN/

For more information see POWERLINK manual:
- ATV320 POWERLINK Manual - VW3A3619: https://www.se.com/ww/en/download/document/NVE41312/
- ATV340 POWERLINK Manual - VW3A3619: https://www.se.com/ww/en/download/document/NVE61681
- ATV600 POWERLINK Manual - VW3A3619: https://www.se.com/ww/en/download/document/PHA99690/
- ATV900 POWERLINK Manual - VW3A3619: https://www.se.com/ww/en/download/document/PHA99693/

Programing manual:
- ATV320 Programming manual: https://www.se.com/ww/en/download/document/NVE41295/
- ATV340 Programming manual https://www.se.com/ww/en/download/document/NVE61643/
- ATV600 Programming manual https://www.se.com/ww/en/download/document/EAV64318
- ATV900 Programming manual https://www.se.com/ww/en/download/document/NHA80757/

Schneider Electric UK

video: How to set POWERLINK between Altivar and B&R PLCs ?
This video explains How to set POWERLINK communication between Altivar Drives and B&R PLCs using the POWERLINK module VW3A3619 with SoMove and Automation Studio.



Download the POWERLINK XDD files VW3A3619 here:  https://www.se.com/in/en/download/document/POWERLINK_XDD_VW3A3619/

Download the POWERLINK adresses:
- ATV320 Communication parameters files here: https://www.se.com/ww/en/download/document/NVE41316/
- ATV340 Communication parameters files here: https://www.se.com/ww/en/download/document/NVE61728/
- ATV600 Communication parameters files here: https://www.se.com/ww/en/download/document/EAV64332/
- ATV900 Communication parameters files here: https://www.se.com/ww/en/download/document/NHA80944/

Download the latest version of the DTM:
- Altivar ATV320 DTM here: https://www.se.com/ww/en/download/document/ATV320_DTM_Library/
- Altivar ATV340 DTM here: https://www.se.com/ww/en/download/document/ATV340_DTM_LibraryEN/
- Altivar ATV600 DTM here:  https://www.se.com/ww/en/download/document/ATV6xx_DTM_Library_EN/
- Altivar ATV900 DTM here: https://www.se.com/ww/en/download/document/ATV9xx_DTM_Library_EN/

For more information see POWERLINK manual:
- ATV320 POWERLINK Manual - VW3A3619:   https://www.se.com/ww/en/download/document/NVE41312/
- ATV340 POWERLINK Manual - VW3A3619:   https://www.se.com/ww/en/download/document/NVE61681
- ATV600 POWERLINK Manual - VW3A3619:  https://www.se.com/ww/en/download/document/PHA99690/
- ATV900 POWERLINK Manual - VW3A3619:   https://www.se.com/ww/en/download/document/PHA99693/  

Programing manual:
- ATV320 Programming manual: https://www.se.com/ww/en/download/document/NVE41295/
- ATV340 Programming manual https://www.se.com/ww/en/download/document/NVE61643/
- ATV600 Programming manual https://www.se.com/ww/en/download/document/EAV64318
- ATV900 Programming manual https://www.se.com/ww/en/download/document/NHA80757/
 
 

Schneider Electric UK

Users group

Discuss this topic with experts

Visit our Community for first-hand insights from experts and peers on this topic and more.
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
move-arrow-top
Your browser is out of date and has known security issues.

It also may not display all features of this website or other websites.

Please upgrade your browser to access all of the features of this website.

Latest version for Google Chrome, Mozilla Firefox or Microsoft Edgeis recommended for optimal functionality.