How to enable OCPP EV presence notification when using Digital input for EVlink Pro AC ?
In case you use the Digital input E5/E6 for vehicle detection : the EV presence will change the LED stripe status to blue and log as "preparing".

If you need the OCCP to manage the EV presence notification through DataTransfer, it's necessary to enable the function by changing the OCPP configuration key "EvPresenceNotification" to " True".

You can find the list of OCPP configurations keys in the official document GEX1969200 - Ocpp conectivity guide, available on se.com