Issue:
Catalog numbers needed for replacement jumper kits for 9070 Class Control Transformers

Product Line:
LV Transformers

Environment:
Applies to 9070 Class Control Transformers by Square D/Schneider Electric only

Cause:
Jumper kits are needed to interconnect primary and/or secondary windings on some (but not all) 9070 Class Control Transformers, to achieve various voltage input/output options

Resolution:
Yes.  As noted on page 8 of the Industrial Control Transformer Catalog, document # 9070CT9901, replacement jumper kits contain 2 jumpers per kit and must be ordered in minimum quantities of 50 kits.

Use kit number 30033-027-53 for accessory key I - 25 to 200 VA. and accessory key II - 25 to 150 VA.

Use kit number 30033-027-54 for accessory key I - 250 to 5000 VA, accessory key II - 200 to 3000 VA, and accessory key III - 25 to 3000 VA.

The following video demonstrates the differences between the jumpers included with 9070 series transformers:

Schneider Electric USA

Video: Are replacement jumper kits offered for Square D/Schneider Electric's 9070 Type T and TF industrial control transformers?

Issue:
Catalog numbers needed for replacement jumper kits for 9070 Class Control Transformers

Product Line:
LV Transformers

Environment:
Applies to 9070 Class Control Transformers by Square D/Schneider Electric only

Cause:
Jumper kits are needed to interconnect primary and/or secondary windings on some (but not all) 9070 Class Control Transformers, to achieve various voltage input/output options

Resolution:
Yes.  As noted on page 8 of the Industrial Control Transformer Catalog, document # 9070CT9901, replacement jumper kits contain 2 jumpers per kit and must be ordered in minimum quantities of 50 kits.

Use kit number 30033-027-53 for accessory key I - 25 to 200 VA. and accessory key II - 25 to 150 VA.

Use kit number 30033-027-54 for accessory key I - 250 to 5000 VA, accessory key II - 200 to 3000 VA, and accessory key III - 25 to 3000 VA.

The following video demonstrates the differences between the jumpers included with 9070 series transformers:

Schneider Electric USA

Explore more
Range:
Explore more
Range:
Users group

Discuss this topic with experts

Visit our Community for first-hand insights from experts and peers on this topic and more.
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Range:
Explore more
Range:
move-arrow-top
Your browser is out of date and has known security issues.

It also may not display all features of this website or other websites.

Please upgrade your browser to access all of the features of this website.

Latest version for Google Chrome, Mozilla Firefox or Microsoft Edgeis recommended for optimal functionality.
Your browser is out of date and has known security issues.

It also may not display all features of this website or other websites.

Please upgrade your browser to access all of the features of this website.

Latest version for Google Chrome, Mozilla Firefox or Microsoft Edgeis recommended for optimal functionality.
Your browser is out of date and has known security issues.

It also may not display all features of this website or other websites.

Please upgrade your browser to access all of the features of this website.

Latest version for Google Chrome, Mozilla Firefox or Microsoft Edgeis recommended for optimal functionality.