What replaces the Q1 tenant breakers used in the old obsolete 100 A sockets for vertical and unitized EZ Stack, multi-metering devices?

Article available in these languages: Spanish

Issue:
Is there a suggested replacement for Q12100 breaker in the obsolete EZM or UEZM devices?

Product Line:
Residential metering equipment

Resolution:
The 100 A, vertical and unitized EZ Stack devices accepted either QO or Q1 tenant breakers, 2 pole, 15 - 100 A. QO breakers were used for requirements from 15 through 70 A (inclusive) and Q1 breakers were used for requirements for 70 through 100 A (inclusive). The Q1 breakers are obsolete and no longer available, but can be replaced by QO breakers.