Our Brands

Impact-Company-Logo-English Black-01-177x54

Schneider Electric USA Website

Welcome to our website.
How can we help you today?
Video: What is the difference between the HOM2150/HOM2200 and the HOM2150BB/HOM2200BB?
Issue:
Differentiating HOM2150/HOM2200 & HOM2150BB/HOM2200BB Circuit Breakers

Product Line:
Homeline Load centers

Resolution:
The older designed catalog numbers HOM2150 and HOM2200 were used as main breakers in the old obsolete Series 1 and 2 Homeline main breaker load centers. These main breakers are still used today in a few CSEDs (combination service entrance devices).

The HOM2150BB and HOM2200BB are designed ONLY to be used as branch breakers for use ONLY in the current Series S01 - S04 Homeline load centers rated 150 A max or higher.

NOTE: The HOM2150 and HOM2200 are NOT designed the same so they CANNOT be used as branch breakers and the current branch breakers, HOM2--BB, CANNOT be used as mains in the old obsolete panels.

Schneider Electric USA

Explore more
Range:
Articles that might be helpful Users group

Discuss this topic with experts

Visit our Community for first-hand insights from experts and peers on this topic and more.
Explore more
Range: