What are the repair parts for an H365N, series E4 heavy duty safety switch?
Issue:
Repair parts

Product Line:
Heavy Duty Safety Switches

Resolution:
The parts listed here are the only field replaceable parts.
Line base assembly - 4055218850 (3 required; arc suppressor assembly not included)
Load base assembly - 4055219050SEL (3 required)
Arc suppressor assembly - 4051270850 (3 required)
Lug assembly - 4025113650 (1 required per base assembly)
Neutral assembly - 4055225250SEL
Line base phase insulator - 4051201401 (2 required)
Load base phase insulator - 4055219101 (1 required)
Line and load base mounting screws - 4020600901 (2 required per base assembly)
Handle assembly - 4051217251
Handle knob kit - 4028343550
Door thumb screw and retainer - 2 each of 4405043401 (screw) and 4405043301 (retainer)
Neutral bonding strap - 4028337950SEL
Center Cross bar insulator - 4055217801 (1 required)
Outside Cross bar insulators - 4055217701 (2 required)
Dust Shield - 4055215701 (1 required)

Schneider Electric USA

What are the repair parts for an H365N, series E4 heavy duty safety switch?
Issue:
Repair parts

Product Line:
Heavy Duty Safety Switches

Resolution:
The parts listed here are the only field replaceable parts.
Line base assembly - 4055218850 (3 required; arc suppressor assembly not included)
Load base assembly - 4055219050SEL (3 required)
Arc suppressor assembly - 4051270850 (3 required)
Lug assembly - 4025113650 (1 required per base assembly)
Neutral assembly - 4055225250SEL
Line base phase insulator - 4051201401 (2 required)
Load base phase insulator - 4055219101 (1 required)
Line and load base mounting screws - 4020600901 (2 required per base assembly)
Handle assembly - 4051217251
Handle knob kit - 4028343550
Door thumb screw and retainer - 2 each of 4405043401 (screw) and 4405043301 (retainer)
Neutral bonding strap - 4028337950SEL
Center Cross bar insulator - 4055217801 (1 required)
Outside Cross bar insulators - 4055217701 (2 required)
Dust Shield - 4055215701 (1 required)

Schneider Electric USA

Explore more
Product:
Explore more
Product:
Users group

Discuss this topic with experts

Visit our Community for first-hand insights from experts and peers on this topic and more.
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Product:
Explore more
Product:
move-arrow-top
Your browser is out of date and has known security issues.

It also may not display all features of this website or other websites.

Please upgrade your browser to access all of the features of this website.

Latest version for Google Chrome, Mozilla Firefox or Microsoft Edgeis recommended for optimal functionality.
Your browser is out of date and has known security issues.

It also may not display all features of this website or other websites.

Please upgrade your browser to access all of the features of this website.

Latest version for Google Chrome, Mozilla Firefox or Microsoft Edgeis recommended for optimal functionality.
Your browser is out of date and has known security issues.

It also may not display all features of this website or other websites.

Please upgrade your browser to access all of the features of this website.

Latest version for Google Chrome, Mozilla Firefox or Microsoft Edgeis recommended for optimal functionality.