Video: What ampere settings are available on PowerPact H, J and L frame breakers?

Article available in these languages: Spanish

Issue:
What ampere settings are available on PowerPact H, J and L frame breakers?

Product Line:
PowerPact H, J and L frame breakers

Environment:
This applies to all PowerPact H, J and L frame breakers with any Micrologic trip unit.

Cause:
The product was purchased before the full load current of the system was known and the ampere rating of the breaker needs to be changed without replacing it.

Resolution:
Here are the settings available for the PowerPact H, J and L frame breakers with Micrologic Standard Trip Units.
 
If In value equals...then available Ir dial settings are...
60 A15, 20, 25, 30, 35, 40, 45, 50, 60 A
100 A35, 40, 45, 50, 60, 70, 80, 90, 100 A
150 A50, 60, 70, 80, 90, 100, 110, 125, 150 A
250 A70, 80, 100, 125, 150, 175, 200, 225, 250 A
400 A125, 150, 175, 200, 225, 250, 300, 350, 400 A
600 A200, 225, 250, 300, 350, 400, 450, 500, 600 A

If Micrologic Ammeter or Energy Trip Units are used each of these settings may be adjusted down 1A at a time down to the minimum setting using the trip unit display.
Once completed a MICROTUSEAL can be added to the face of the trip unit to prevent tampering of the settings.
  • I-Line L frame circuit breakers with advanced trip units (Ammeter or Energy style) are available only with 400A or 600A sensor.
  • Settings below minimum dial setting is not possible.  Settings above maximum dial setting is not possible.
  • 100% ratings are not available for 600A sensor.
  • NOTE:  The ampere rating on H and J frame thermal-magnetic breakers can NOT be adjusted, however you can adjust the magnetic trip setting on J-frame thermal-mag breakers.
The following video demonstrates how to manage these settings:

Trip unit video

H and J Frame
3.2 trip unit
3.2S trip unit
5.0A trip unit
6.0A trip unit

L Frame
3.3 trip unit
3.3S trip unit
5.3A trip unit
6.3A trip unit

Schneider Electric USA

Explore more
Range:
Users group

Discuss this topic with experts

Visit our Community for first-hand insights from experts and peers on this topic and more.
Explore more
Range:
move-arrow-top
Your browser is out of date and has known security issues.

It also may not display all features of this website or other websites.

Please upgrade your browser to access all of the features of this website.

Latest version for Google Chrome, Mozilla Firefox or Microsoft Edgeis recommended for optimal functionality.
Your browser is out of date and has known security issues.

It also may not display all features of this website or other websites.

Please upgrade your browser to access all of the features of this website.

Latest version for Google Chrome, Mozilla Firefox or Microsoft Edgeis recommended for optimal functionality.
Your browser is out of date and has known security issues.

It also may not display all features of this website or other websites.

Please upgrade your browser to access all of the features of this website.

Latest version for Google Chrome, Mozilla Firefox or Microsoft Edgeis recommended for optimal functionality.