{}

Our Brands

Impact-Company-Logo-English Black-01-177x54

Schneider Electric USA Website

Welcome to our website.
How can we help you today?
How to get access on ILX2T?

Goals and Symptoms

How to get access on ILX2T?

Causes and Fixes

To write parameters via Modbus TCP, e.g. the control word, the plc must take the access rights before. This happens by writing the value 1 to parameter 282.

Attention:
This is not necessary if the IOscanning with Unit-ID 255 is used.


Legacy KB System (APS) Data: RESL201667 V1.0, Originally authored by PaFr on 03/18/2010, Last Edited by PaFr on 03/18/2010
Related ranges: Lexium ILA, ILE, ILS

Schneider Electric USA

Explore more
Range:
Articles that might be helpful Users group

Discuss this topic with experts

Visit our Community for first-hand insights from experts and peers on this topic and more.
Explore more
Range: