{}

Our Brands

Impact-Company-Logo-English Black-01-177x54

Schneider Electric USA Website

Welcome to our website.
How can we help you today?
What's the difference between a Located and Unlocated Variable in the Unity Pro software?

Issue
Difference between a Located and Unlocated Variable in Unity Pro

Product Line
Unity Pro

Environment
Unity Pro

Resolution
A Located Variable is a variable that is either mapped to an I/O Module or is associated to a Memory reference.
An Unlocated variable is a variable which is not mapped to the I/O or associated to a Memory reference (it is not possible to know its position in memory). A variable which has no address assigned is said to be unlocated.

Schneider Electric USA

Explore more
Range:
Articles that might be helpful Users group

Discuss this topic with experts

Visit our Community for first-hand insights from experts and peers on this topic and more.
Explore more
Range: