Red/High Leg Delta Configuration for ION and PM8000 meters

Product Line:
ION Meters
PM8000 series meters

Environment:
Voltage Configuration

Resolution:
*Warning: Installation and maintenance of this device should only be performed by qualified, competent personnel that have appropriate training and experience with high voltage and current devices. Failure to follow the instructions / warnings in the Meter Installation Guide can result in permanent damage to the meter, severe injury or death.


The attached document discusses Red Leg Delta (also called "High Leg Delta") configuration and how it works in WYE Mode and DELTA Mode.
The document can also be downloaded from here

Schneider Electric USA

Attachment(s)
7EN72-0168-03.pdf [147.88 KB]
Red/High Leg Delta Configuration for ION and PM8000 meters

Product Line:
ION Meters
PM8000 series meters

Environment:
Voltage Configuration

Resolution:
*Warning: Installation and maintenance of this device should only be performed by qualified, competent personnel that have appropriate training and experience with high voltage and current devices. Failure to follow the instructions / warnings in the Meter Installation Guide can result in permanent damage to the meter, severe injury or death. 

 
The attached document discusses Red Leg Delta (also called "High Leg Delta") configuration and how it works in WYE Mode and DELTA Mode.
The document can also be downloaded from here

Schneider Electric USA

Attachment(s)
7EN72-0168-03.pdf [147.88 KB]
Explore more
Range:
Explore more
Range:
Users group

Discuss this topic with experts

Visit our Community for first-hand insights from experts and peers on this topic and more.
Users group

Discuss this topic with experts

Visit our Community for first-hand insights from experts and peers on this topic and more.
Explore more
Range:
Explore more
Range:
move-arrow-top
Your browser is out of date and has known security issues.

It also may not display all features of this website or other websites.

Please upgrade your browser to access all of the features of this website.

Latest version for Google Chrome, Mozilla Firefox or Microsoft Edgeis recommended for optimal functionality.
Your browser is out of date and has known security issues.

It also may not display all features of this website or other websites.

Please upgrade your browser to access all of the features of this website.

Latest version for Google Chrome, Mozilla Firefox or Microsoft Edgeis recommended for optimal functionality.
Your browser is out of date and has known security issues.

It also may not display all features of this website or other websites.

Please upgrade your browser to access all of the features of this website.

Latest version for Google Chrome, Mozilla Firefox or Microsoft Edgeis recommended for optimal functionality.