What is the difference between a “Normal Stop” and “Emergency Stop” versions of the XY2 cable pull switches?
Issue:
What is the difference between a “Normal Stop” and “Emergency Stop” versions of the XY2 cable pull switches?
Product Line:
Cable Pull Switches
Environment:
Machine Safety Products
Cause:
Product Selection
Resolution:
The Emergency stop versions have positive opening Normally Closed contacts that latch upon tripping (positive opening) and must be manually reset.
Normal stop versions are used where a momentary, non-emergency signal is required at any point along a cable. These devices have snap acting contacts and are non-latching devices.