{}

Our Brands

Impact-Company-Logo-English Black-01-177x54

Schneider Electric USA Website

Welcome to our website.
How can we help you today?
What data formats for CAM profiles are available in SoMachine?

Article available in these languages: Czech

CAM profiles can be saved in 3 different formats:
1) Poly - there are master position, slave position, slave velocity, and slave acceleration defined in each point, this gives 6 border conditions and it is possible to fit it with a polynomial of 5th degree.
2) 1D - there are equidistant points for master range and in every point, there is a slave position. it is possible to use linear or cubic interpolation
3) 2D - same as 1D, but the coordinates of the master are defined and they have not to be equidistant.

Schneider Electric USA

Explore more
Range:
Articles that might be helpful Users group

Discuss this topic with experts

Visit our Community for first-hand insights from experts and peers on this topic and more.
Explore more
Range: