What does Rx and Lx suffix mean on HC or I-Line enclosures? (Example: HC4286DBR5 or HC4286DBL5)
Issue:
I-Line Enclosure suffixes for side wall extensions

Product Line:
I-Line Panelboards

Environment:
Panelboard Enclosures

Resolution:
"R" means right side and "L" means left side. The number means how many inches would be the extensions.

On the attachment, it shows a box for an HC4486DBL5. It shows the uncentered positions of the studs where the I-line interior would be mounted, thus, portraying the extension provided on the left side of the enclosure.

Schneider Electric USA

Attachment(s)
HC4486DBL5.pdf [173.56 KB]
What does Rx and Lx suffix mean on HC or I-Line enclosures? (Example: HC4286DBR5 or HC4286DBL5)
Issue:
I-Line Enclosure suffixes for side wall extensions

Product Line:
I-Line Panelboards

Environment:
Panelboard Enclosures

Resolution:
"R" means right side and "L" means left side. The number means how many inches would be the extensions.

On the attachment, it shows a box for an HC4486DBL5. It shows the uncentered positions of the studs where the I-line interior would be mounted, thus, portraying the extension provided on the left side of the enclosure.

Schneider Electric USA

Attachment(s)
HC4486DBL5.pdf [173.56 KB]
Explore more
Range:
Explore more
Range:
Users group

Discuss this topic with experts

Visit our Community for first-hand insights from experts and peers on this topic and more.
Users group

Discuss this topic with experts

Visit our Community for first-hand insights from experts and peers on this topic and more.
Explore more
Range:
Explore more
Range:
move-arrow-top
Your browser is out of date and has known security issues.

It also may not display all features of this website or other websites.

Please upgrade your browser to access all of the features of this website.

Latest version for Google Chrome, Mozilla Firefox or Microsoft Edgeis recommended for optimal functionality.
Your browser is out of date and has known security issues.

It also may not display all features of this website or other websites.

Please upgrade your browser to access all of the features of this website.

Latest version for Google Chrome, Mozilla Firefox or Microsoft Edgeis recommended for optimal functionality.
Your browser is out of date and has known security issues.

It also may not display all features of this website or other websites.

Please upgrade your browser to access all of the features of this website.

Latest version for Google Chrome, Mozilla Firefox or Microsoft Edgeis recommended for optimal functionality.