HMIDT642 and HMIG3U Harsh Environment HMI version

ISSUE:

Looking for Harsh environment HMI version of the HMIG3U and HMIDT642.

PRODUCT LINE:

Harmony HMI, Magelis HMI, HMIGTU, HMIGTUX

RESOLUTION:

As a first upgrade for harsh environment, almost (but not all, ask your local distributor or sales representative) of the products in the catalog for "Harmony GTU - High performance IoT-ready modular HMI panels" are available with a conformal coating applied at the factory. Note that these are not stock, when ordered a delivery time of 4 weeks is to be added.

Link to catalog:

https://download.schneider-electric.com/files?p_enDocType=Catalog&p_File_Name=Catlaog+Harmoy+GTU+-+High+performance+IoT-ready+modular+HMI+panel.pdf&p_Doc_Ref=DIA5ED2140401EN

For the HMIG3U and HMIDT642, the following might be looked at:

HMIG3UFC:

https://www.se.com/us/en/product/HMIG3UFC/base-unit%2C-harmony-gtu%2C-premium-box-for-universal-panel/

Compatible with display:

HMIDT351FC:

https://www.se.com/us/en/product/HMIDT351FC/advanced-touchscreen-panel%2C-harmony-gtu%2C-7-w-touch-display-wvga%2C-coated-display/

HMIDT551FC:

https://www.se.com/us/en/product/HMIDT551FC/advanced-touchscreen-panel%2C-harmony-gtu%2C-10-w-touch-display-wxga%2C-coated-display/

HMIDT651FC:

https://www.se.com/us/en/product/HMIDT651FC/advanced-touchscreen-panel%2C-harmony-gtu%2C-12-w-touch-display-wxga%2C-coated-display/

HMIDT542FC:

https://www.se.com/us/en/product/HMIDT542FC/flat-screen%2C-harmony-gtu%2C-10.4-touch-smart-display-svga%2C-coated-display/

HMIDT642FC:

https://www.se.com/us/en/product/HMIDT642FC/flat-screen%2C-harmony-gtu%2C-12.1-touch-smart-display-xga%2C-coated-display/

HMIDT732FC:

https://www.se.com/us/en/product/HMIDT732FC/flat-screen%2C-harmony-gtu%2C-15-touch-smart-display-xga%2C-coated-display/

For a more resistant product, look at the Harmony GTUX - eXtreme outdoor HMI panels harsh outdoor environment family of product.

Link to catalog:

https://download.schneider-electric.com/files?p_enDocType=Catalog&p_File_Name=Catalog+Harmony+GTUX+eXtreme+outdoor+HMI+panels.pdf&p_Doc_Ref=DIA5ED2181203EN

HMIG3X:

https://www.se.com/us/en/product/HMIG3X/base-unit%2C-harmony-gtux%2C-serie-extreme-box-outdoor-use%2C-rugged%2C-coated/

Compatible with display:

HMIDT35X

https://www.se.com/us/en/product/HMIDT35X/harmony-gtux-series-extreme-display-7.0-inch-wide%2C-outdoor-use%2C-rugged%2C--coated/

HMIDT65X

https://www.se.com/us/en/product/HMIDT65X/harmony-gtux-series-extreme-display-12.0-inch-wide%2C-outdoor-use%2C-rugged%2C--coated/

HMIDT75X

https://www.se.com/us/en/product/HMIDT75X/harmony-gtux-series-extreme-display-15.0-inch-wide%2C-outdoor-use%2C-rugged%2C--coated/

-----

HMIG3XFH:

https://www.se.com/us/en/product/HMIG3XFH/base-unit%2C-harmony-gtux%2C-serie-extreme-box-full-coated/

Compatible with display:

HMIDT35XFH:

https://www.se.com/us/en/product/HMIDT35XFH/extreme-touchscreen-panel%2C-harmony-gtux%2C-7-w-display-full-coated/

HMIDT65XFH:

https://www.se.com/us/en/product/HMIDT65XFH/extreme-touchscreen-panel%2C-harmony-gtux%2C-12-w-display-full-coated/

HMIDT75XFH:

https://www.se.com/us/en/product/HMIDT75XFH/extreme-touchscreen-panel%2C-harmony-gtux%2C-15-w-display-full-coated/

NOTES:

Harmony GTU and Harmony GTUX display modules and box modules are not compatible with each other because of firmware incompatibilities.

To maintain the environmental rating of the devices, an FC box should be paired with a FC display, a X module with a X display and a XFH box with a XFH display.