video: How to reduce Harmonics with passive filter and set iFi [Input Filter] function on ATV600, ATV900 ?

🎥 Looking to learn more about harmonic reduction and configuring the iFi function?

In this video, dive into the realm of passive filters and discover how they can help mitigate unwanted harmonics.

We'll also provide an in-depth explanation of configuring the iFi function to optimize its usage.



🔔 Timestamps:
0:13 - Introduction
0:38 - Harmonics and Altivar Process Drives
1:27 - Passive filter
3:07 - Connection with shunt
3:37 - Connection with contactor
4:39 - General Programming
6:22 - Importance of using [Input Filter] iFi parameter

➡️For more information see:
● Catalog for Altivar Process ATV600: https://www.se.com/ww/en/download/document/DIA2ED2140502EN/
● Catalog for Altivar Process ATV900: https://www.se.com/ww/en/download/document/DIA2ED2150601EN/
● ATV630-650 Installation manual: https://www.se.com/ww/en/download/document/EAV64301/
● ATV930-950 Installation manual: https://www.se.com/ww/en/download/document/NHA80932/
● Instruction sheet - ATV Passive Filters - VW3A46101 ... A46176 : https://www.se.com/ww/en/download/document/EAV38321/
● Instruction Sheet: Passive filters - VW3A46101A ... VW3A46116A: https://www.se.com/ww/en/download/document/NHA88101/
● Instruction Sheet: Passive filter VW3A46117A : https://www.se.com/ww/en/download/document/NNZ63894/
● Instruction Sheet - Passive filters VWA346118A...VW3A46121A: https://www.se.com/ww/en/download/document/NNZ37670/
● Instruction Sheet: Passive Filters VW3A46122A...VW3A46181A: https://www.se.com/ww/en/download/document/BQT77693/

Schneider Electric USA

video: How to reduce Harmonics with passive filter and set iFi [Input Filter] function on ATV600, ATV900 ?

🎥 Looking to learn more about harmonic reduction and configuring the iFi function?

In this video, dive into the realm of passive filters and discover how they can help mitigate unwanted harmonics.

We'll also provide an in-depth explanation of configuring the iFi function to optimize its usage.



 

🔔 Timestamps: 
0:13 - Introduction 
0:38 - Harmonics and Altivar Process Drives
1:27 - Passive filter 
3:07 - Connection with shunt
3:37 - Connection with contactor
4:39 - General Programming
6:22 - Importance of using [Input Filter] iFi parameter

➡️For more information see: 
● Catalog for Altivar Process ATV600: https://www.se.com/ww/en/download/document/DIA2ED2140502EN/
● Catalog for Altivar Process ATV900:  https://www.se.com/ww/en/download/document/DIA2ED2150601EN/
● ATV630-650 Installation manual: https://www.se.com/ww/en/download/document/EAV64301/
● ATV930-950 Installation manual: https://www.se.com/ww/en/download/document/NHA80932/
● Instruction sheet - ATV Passive Filters - VW3A46101 ... A46176 :  https://www.se.com/ww/en/download/document/EAV38321/
● Instruction Sheet: Passive filters - VW3A46101A ... VW3A46116A:  https://www.se.com/ww/en/download/document/NHA88101/
● Instruction Sheet: Passive filter VW3A46117A : https://www.se.com/ww/en/download/document/NNZ63894/
● Instruction Sheet - Passive filters VWA346118A...VW3A46121A: https://www.se.com/ww/en/download/document/NNZ37670/
● Instruction Sheet: Passive Filters VW3A46122A...VW3A46181A: https://www.se.com/ww/en/download/document/BQT77693/

 

Schneider Electric USA

Explore more
Range:
Explore more
Range:
Users group

Discuss this topic with experts

Visit our Community for first-hand insights from experts and peers on this topic and more.
Users group

Discuss this topic with experts

Visit our Community for first-hand insights from experts and peers on this topic and more.
Explore more
Range:
Explore more
Range:
move-arrow-top
Your browser is out of date and has known security issues.

It also may not display all features of this website or other websites.

Please upgrade your browser to access all of the features of this website.

Latest version for Google Chrome, Mozilla Firefox or Microsoft Edgeis recommended for optimal functionality.
Your browser is out of date and has known security issues.

It also may not display all features of this website or other websites.

Please upgrade your browser to access all of the features of this website.

Latest version for Google Chrome, Mozilla Firefox or Microsoft Edgeis recommended for optimal functionality.