You are currently viewing the content available in Vietnam. If you are looking for information for another region, please select the correct country from the top-left dropdown in the page and 'Navigate to Browse FAQs' in the Support menu.
Issue:
Why is the LED scrolling on the ATV312?
Product Line:
Altivar 312, Altivar 12
Environment:
All serial numbers
Cause:
N/A
Resolution:
The scrolling LEDs mean the drive is in Local Operation mode. To switch into Local Programming, push and hold the ESC button for 2s. Then all three LED's will be flashing at the same time and the programming can be changed. When programming is finished, push and hold the ESC button again for 2s to enter into Local Operation again.
To switch back into Remote mode, push and hold the Mode button for 3s. Note - some programming is reset to factory defaults if you switch between Local and Remote. The drive is intended to be used for Local or Remote, not Local and Remote
Why is the LED scrolling on the ATV312?
Product Line:
Altivar 312, Altivar 12
Environment:
All serial numbers
Cause:
N/A
Resolution:
The scrolling LEDs mean the drive is in Local Operation mode. To switch into Local Programming, push and hold the ESC button for 2s. Then all three LED's will be flashing at the same time and the programming can be changed. When programming is finished, push and hold the ESC button again for 2s to enter into Local Operation again.
To switch back into Remote mode, push and hold the Mode button for 3s. Note - some programming is reset to factory defaults if you switch between Local and Remote. The drive is intended to be used for Local or Remote, not Local and Remote