You are currently viewing the content available in Vietnam. If you are looking for information for another region, please select the correct country from the top-left dropdown in the page and 'Navigate to Browse FAQs' in the Support menu.
Issue:
Factory reset on the ATV320 drive.
Product Line:
Altivar 320
Environment:
All
Cause:
Factory reset.
Resolution:
To perform a factory reset from power up;
Enter on dial.
Scroll to CONF menu and enter.
Scroll to FCS- and enter.
Scroll to FRY- and enter.
Select All so that " mark is at top instead of bottom.
Now go to GFS parameter.
Set it to YES and hold enter for 2 seconds until display LEDs stop flashing.
VFD is rest to factory defaults.
Factory reset on the ATV320 drive.
Product Line:
Altivar 320
Environment:
All
Cause:
Factory reset.
Resolution:
To perform a factory reset from power up;
Enter on dial.
Scroll to CONF menu and enter.
Scroll to FCS- and enter.
Scroll to FRY- and enter.
Select All so that " mark is at top instead of bottom.
Now go to GFS parameter.
Set it to YES and hold enter for 2 seconds until display LEDs stop flashing.
VFD is rest to factory defaults.